![]() Usage/Application: Viscosity of paints, inks, lacquers and other liquids. Manufactured in chromed seel in 5 models (5 to 180 centistokes). Gardner Company and licensed distributors. Brass Ford Cup Viscosity Measuring Cup ELCOTEST. Inmersion cup for the simple and practical measuring of the viscosity of paints, inks, lacquers and other liquids. The applicable formula and table are furnished with each cup sold as an additional customer service by the Paul N. ![]() Conversion from viscosity to efflux time in seconds is by formula or table which defines the characteristics of the cup. The standard oil value in centistokes is printed on the standard oil bottle label. For best accuracy, the temperature of the standard oil should be 25☌. The cup may be checked with the indicated “G” oil with reasonable accuracy within these limits. By going through the authentication and verification process, can only check that the business is registered in its local business administration. Efflux time in seconds for the indicated cup-oil combination from twenty (20) to twenty seven (27) degrees Celsius is shown in the graph. Viscosity of most liquids, including the standard oils, are dependent on temperature. Graphs for all cups in the EZ series are included with each cup sold by Paul N. Normally, cup calibration is at 25 degrees Celsius, shown on the graph by bold lines intersecting with the curve in the circle. Cup allows you to verify coating viscosity prior to painting, so you can fully atomize the paint spray, helping you achieve a flawless finish. The instrument used throughout the industry since 1934 is called a Viscosity Cup or Stein-Hall Cup. Shown in the graph is the viscosity cup number and the standard “G” oil used for its calibration. The Ford 4 cup is a portable device for quickly checking and measuring the viscosity or thickness of paint, varnish, lacquer, stains, inks, syrups, liquids and more. These oils are available from the Paul N. Gardner Company are produced in accordance with ISO/IEC 17025:2005, ISO/IEC Guide 34:2009, ISO 9001:2008.Ĭentistokes viscosity of these oils is traceable to the National Institute of Standards and Technology. These standard calibration oils prepared expressly by the Cannon Instrument Company for the Paul N. Reactor Systems Synthesis Reactors High Viscosity Reactors Photo Bioreactors. Gardco produced viscosity cups are calibrated with standard “G” series oils. Measuring Viscosity Measuring stirrers Viscometers Heating / Cooling. Solvent washings from these viscometers should not be used for cleaning other viscometers. The following is taken from ASTM D 445: Viscometers used for silicone fluids should be reserved for the exclusive use of such fluids. For easy measurement of the viscosity of paints, inks, lacquers and. Now you have recorded information that you can definitely rely on. As an example: 30.6 seconds, Gardco EZ Cup 2, 61.3 centistokes viscosity 77° F (25° C). These materials change the interface between the cup surface and the test material and therefore change the cup calibration. Our Ford Cups are in accordance with International Standard ASTM D1200, D333, and D365. We recommend that you also include the cup maker’s name in your report as well as temperature at time of test. Warning: Silicone fluids should not be used to calibrate viscosity cups.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |